We provide customized surface drug residue test kits for commercial clients based on their specific requirements. Customization options may include target substances and detection sensitivity. Minimum order quantity starts at 1,000 units. Pricing is available upon consultation.
1
Retail Order
For smaller quantities, order the Aiscenovica 8-panel surface and oral drug test kit (5-pack). The retail kit has a fixed panel; custom panels and sensitivities require a commercial order.
2
Commercial order or customization
We supply multi-panel drug test kits to businesses and law enforcement agencies. For surface drug residue screening, results are read within 5–10 minutes, depending on the selected kit.
Available panels may include 6-AM, BAR, COC (cocaine), FEN (fentanyl), KET, THC, MET, MTD, MOR, OXY, PCP, PPX, TRA, AMP, BZO and BUP.
The device is portable and easy to use. For oral fluid drug testing, the multi-panel drug test device can complete saliva collection in 1-2 seconds, requiring as little as 80 µL of sample.
Results are available in 5-10 minutes (time to read results), making it suitable for on-site testing.
Negative Results: A red-colored band should be observed in the control region (C) and the specific drug test region. The color and density of the test band may vary for control and drug test regions.
Presumptive Positive Results: When the control band is visible in the control region (C) and no band appears at the specific test region, the result is a presumptive positive for that particular drug.
Invalid: When no band appears in the control (C) region, the test is invalid regardless of the results in the test region. If the test is invalid, check testing procedures. Repeat the test using a new device.
Available cut-off levels:
-
6-AM: 10 ng/mL
-
AMP: 50 ng/mL
-
BAR: 25/50 ng/mL
-
BZO: 10/20 ng/mL
-
BUP: 10 ng/mL
-
KET: 50 ng/mL
-
MTD: 30 ng/mL
-
OXY: 40 ng/mL
-
PCP: 10 ng/mL
-
PPX: 25 ng/mL
-
TRA: 25 ng/mL
-
MOR: 10 ng/mL
-
MET: 25/50 ng/mL
-
THC: 25 ng/mL
-
COC (cocaine): 10/20/50 ng/mL
-
FEN (fentanyl): 20 ng/mL
Cross-reactivity: Some substances may interfere with results (e.g., amphetamine and opioid derivatives).
Intended use: Law enforcement, institutional and workplace safety, scientific and industrial use, and screening vape liquids (e-cigarette oil) for illicit substances. For forensic use only; not for diagnostic use.
For post-cleaning screening, select a kit whose target substances, sample type and cut-offs match the assessment.
A negative result indicates that the selected drugs were not detected at or above the kit's stated cut-offs in the tested sample. This helps document cleaning results at the sampled locations.